The evaporator coil of a wine cellar cooling unit seen through its supply grille, the aluminum fins crusted white with ice, a few drops gathering at the lower edge.

CellarCool Ad2: the coil was still frozen when defrost timed out

Ad2 on a CellarCool Ceiling Mount, split or Ultimate unit records an Anti-Frost cycle that timed out.

(844) 398-5977

Mon–Sat, 8am–8pm

  • Coil icing and defrost
  • Cellar coil icing and defrost repair
  • Source: CellarCool

Book a visit

Three short steps, about a minute.

or call (844) 398-5977

What Ad2
actually means.

Ad2 on a CellarCool Ceiling Mount, split or Ultimate unit records an Anti-Frost cycle that timed out. Ice is forming faster than the cycle clears it, which points to dirty filters or coils, blocked air, a stopped evaporator fan, a low refrigerant charge or an exhaust space colder than 60°F. CellarCool also names long nonstop running and a setpoint too cold for the room as causes of icing.

CellarCool wine cellar cooling unit display

What to do when Ad2 shows on the wine cellar cooling unit

Before you book,
in this order.

Each step comes from CellarCool's own guidance for Ad2 on its wine cellar cooling units. Follow it to the end: the last card says whether this is a visit.

01

Check the evaporator for ice; unplug the unit and let it thaw, with towels to protect racks and floor.

02

Clean the filter and make sure supply and return air are not blocked.

03

Raise the setpoint if it was set unusually cold.

04

If Ad2 comes back or the unit enters Anti-Frost about once a minute, book a visit.

Still there?

It usually turns into cellar coil icing and defrost repair. Book with the code and the model number.

What not to do

Ad2 is not the ordinary defrost display, which is routine. It is logged in the alarm folder only when a defrost fails to finish.

What you may
notice with it.

The wine cellar cooling unit problems Ad2 tends to arrive with. Answer these at the wine cellar cooling unit before anyone is booked.

All problems

Where Ad2 usually leads

Cellar coil icing and defrost repair.

Thawing an iced coil and correcting its cause · low to moderate.

In CellarCool's own words

The Anti-Frost Cycle ended on time-out
CellarCool CM2500 (Ceiling Mount split) manual, version 4 (02/2022) CellarCool CM2500 (Ceiling Mount split) manual, version 4 (02/2022) CellarCool troubleshooting page

Every code on this site is taken from the manufacturer's documentation, never from a forum or a parts listing. CellarCool split, Ceiling Mount and fully ducted Ultimate controllers (CM2500, 3500-S/5000-S, Ultimate-R manuals). The CX through-the-wall series does not list this code.

CellarCool Ad2 wine cellar cooling unit repair,
where we come out.

The same visit in every metro below: the code, the model number, and a diagnosis before any part is ordered.

All service areas
A couple lifting a bottle from a lit stone-walled wine cellar, the cooling unit's grille high on the far wall
For the heart of your home.

Questions
about Ad2.

Can I clear Ad2 myself?
Check the evaporator for ice; unplug the unit and let it thaw, with towels to protect racks and floor. If it comes back, it needs a visit.
What should I do with the melt water when thawing a CellarCool?
CellarCool asks you to protect racking, walls and floor from the water that runs off. Towels and a shallow tray under the unit usually do it.
Can a very low setpoint cause Ad2 on a CellarCool?
Yes. CellarCool lists a thermostat set too cold for the environment as a cause of icing.
Does the CellarCool CX log Ad2?
No. The CX runs a fixed defrost after two hours of compressor time and does not list Ad2.