CellarCool E2: the evaporator coil probe has lost its connection

E2 on a CellarCool Ceiling Mount, split or Ultimate unit names the evaporator probe, plugged into the PB2 terminal of the circuit board.

(844) 398-5977

Mon–Sat, 8am–8pm

  • Sensors and probes
  • Cellar controller and sensor repair
  • Source: CellarCool

Book a visit

Three short steps, about a minute.

or call (844) 398-5977

What E2
actually means.

E2 on a CellarCool Ceiling Mount, split or Ultimate unit names the evaporator probe, plugged into the PB2 terminal of the circuit board. The controller uses it to start Anti-Frost cycles at about 26°F. Without it, frost can pile up on the coil unnoticed, and the first thing an owner sees may be weaker airflow or water under the unit.

CellarCool wine cellar cooling unit display

What to do when E2 shows on the wine cellar cooling unit

Before you book,
in this order.

Each step comes from CellarCool's own guidance for E2 on its wine cellar cooling units. Follow it to the end: the last card says whether this is a visit.

01

Look at the evaporator coil for frost; if ice has formed, switch the unit off and let it melt, protecting racks and floor from the water.

02

Keep an eye on the cellar temperature, which the bottle probe still controls.

03

Book a visit to reseat or replace the evaporator probe inside the unit.

Still there?

It usually turns into cellar controller and sensor repair. Book with the code and the model number.

What not to do

E2 is not the cellar temperature probe, so the setpoint still holds at first. The risk grows over days, as the coil ices without a defrost trigger.

What you may
notice with it.

The wine cellar cooling unit problems E2 tends to arrive with. Answer these at the wine cellar cooling unit before anyone is booked.

All problems

Where E2 usually leads

Cellar controller and sensor repair.

Air or coil probe, display, transformer or control board · moderate.

In CellarCool's own words

Faulty evaporator probe connection
CellarCool CM2500 (Ceiling Mount split) manual, version 4 (02/2022) CellarCool CM2500 (Ceiling Mount split) manual, version 4 (02/2022) CellarCool CM2500 (Ceiling Mount split) manual, version 4 (02/2022)

Every code on this site is taken from the manufacturer's documentation, never from a forum or a parts listing. CellarCool split, Ceiling Mount and fully ducted Ultimate controllers (CM2500, 3500-S/5000-S, Ultimate-R manuals). The CX through-the-wall series does not list this code.

CellarCool E2 wine cellar cooling unit repair,
where we come out.

The same visit in every metro below: the code, the model number, and a diagnosis before any part is ordered.

All service areas
A couple lifting a bottle from a lit stone-walled wine cellar, the cooling unit's grille high on the far wall
For the heart of your home.

Questions
about E2.

Can I clear E2 myself?
Look at the evaporator coil for frost; if ice has formed, switch the unit off and let it melt, protecting racks and floor from the water. If it comes back, it needs a visit.
Can CellarCool E2 lead to a water leak?
It can. An evaporator that ices without defrosting eventually melts in one go, and the drain pan may not keep up.
Does the CellarCool CX series show E2?
No. The CX alarm table lists only E1, AH1 and AL1.
Is replacing a CellarCool evaporator probe a big job?
It is a small part, but it sits inside the unit on the circuit board terminal, so the unit has to be opened.

Back to your everyday

Still showing E2?

When you book, type the code or the blink count as the controller shows it, add the full model number, and say what the thermometer in the cellar reads now — that gives the technician a head start.

(844) 398-5977 Schedule a repair