Breezaire Er: the Sentry III has lost its temperature sensor
Er means the Sentry III can no longer trust the sensor it regulates from, the intake air sensor or a bottle probe if one is plugged in, so it stops cooling.
Mon–Sat, 8am–8pm
- Sensors and probes
- Cellar controller and sensor repair
- Source: Breezaire
Book a visit
Three short steps, about a minute.
or call (844) 398-5977
Loading appointment form…
The appointment form couldn’t load. Please try again.
What Er
actually means.
Er means the Sentry III can no longer trust the sensor it regulates from, the intake air sensor or a bottle probe if one is plugged in, so it stops cooling. Breezaire lets the owner run the unit by hand in the meantime: COOLER turns it on and WARMER turns it off, each with the 5-minute compressor delay.
Breezaire wine cellar cooling unit display · also shown as ER
What to do when Er shows on the wine cellar cooling unitKind of codeSensors and probes
The controller has lost a sensible reading from one of its probes: the one sampling the cellar air, the one on the evaporator coil, or on a remote probe the lead that runs out to a rack. With no number it can trust, the unit may chill the room well below 55°F, stop and start every few minutes, or run on without end. A probe unplugged during a rack install, pinched behind a board or sitting in a draft from the door is ruled out before a new one is ordered.
Usually leads toCellar controller and sensor repair
Getting the controller, its display and its probes to read the cellar truthfully and call for cooling at the right time.
Shows up asCellar Cooling Unit Error Code
A cellar cooling unit error code appears as letters or digits on the controller, a flashing reading, a blinking light on the unit, or an alarm tone, sometimes while the cellar still holds its temperature.
MakeBreezaire
Visits to cellars cooled by a Breezaire unit, starting with a thermometer among the racks and a hand at the exhaust grille.
SourceBreezaire Sentry III Plus Controller owner's manual
Sentry III and Sentry III Plus controllers on WKL through-the-wall units and WKSL split systems. Older WKS splits built before mid-2010 used a manual thermostat and show none of these codes.
Before you book,
in this order.
Each step comes from Breezaire's own guidance for Er on its wine cellar cooling units. Follow it to the end: the last card says whether this is a visit.
If a bottle probe is fitted, check that its plug is fully seated, because the controller reads the probe in place of the air sensor.
To keep the cellar cool until the repair, press COOLER to start the unit by hand and WARMER to stop it, allowing for the 5-minute delay each time.
Watch the room on a separate thermometer while running by hand, since nothing is regulating the temperature.
Book a visit to test the sensor and its wiring.
Still there?
It usually turns into cellar controller and sensor repair. Book with the code and the model number.
What not to do
Er does not say the cellar is warm or cold; it says the controller cannot tell. LO and HI appear when the sensor still answers but reads below 32°F or above 99°F.
What you may
notice with it.
The wine cellar cooling unit problems Er tends to arrive with. Answer these at the wine cellar cooling unit before anyone is booked.
All problemsWhere Er usually leads
Cellar controller and sensor repair.
Breezaire
wine cellar cooling units.
Visits to cellars cooled by a Breezaire unit, starting with a thermometer among the racks and a hand at the exhaust grille.
Breezaire wine cellar cooling unit repair
Through-the-wall cellar cooling unit
A self-contained box set into an opening in the cellar wall: its cold face blows into the wine room, and its warm face breathes out into the room next door.
Split-system cellar cooling
An evaporator inside or beside the cellar and a condensing unit outside or in another room, joined by an insulated copper line set and charged on site.
In Breezaire's own words
A faulty sensor will be indicated by a display of “Er”.
Every code on this site is taken from the manufacturer's documentation, never from a forum or a parts listing. Sentry III and Sentry III Plus controllers on WKL through-the-wall units and WKSL split systems. Older WKS splits built before mid-2010 used a manual thermostat and show none of these codes.
Breezaire Er wine cellar cooling unit repair,
where we come out.
The same visit in every metro below: the code, the model number, and a diagnosis before any part is ordered.
All service areasTampa BayFL · 31 areas
Miami / South FloridaFL · 47 areas
New York MetroNY · 75 areas
HoustonTX · 36 areas
ChicagoIL · 50 areas
Los AngelesCA · 95 areas
San DiegoCA · 31 areas
Questions
about Er.
Can I clear Er myself?
Can I leave a Breezaire running by hand after Er?
Could a bottle probe be behind Er on my Breezaire?
Will a reset clear Er on a Breezaire?
Back to your everyday
Still showing Er?
When you book, type the code or the blink count as the controller shows it, add the full model number, and say what the thermometer in the cellar reads now — that gives the technician a head start.