Breezaire LO: the sensor is reading below 32°F
LO flashes when the temperature input drops below 32°F.
Mon–Sat, 8am–8pm
- Sensors and probes
- Cellar controller and sensor repair
- Source: Breezaire
Book a visit
Three short steps, about a minute.
or call (844) 398-5977
Loading appointment form…
The appointment form couldn’t load. Please try again.
What LO
actually means.
LO flashes when the temperature input drops below 32°F. In a room kept near 55°F, that points to the sensor, its wiring or where a probe is sitting, rather than to a frozen cellar. Breezaire separately flashes the plain temperature once the reading falls below 43°F, as an earlier prompt.
Breezaire wine cellar cooling unit display · also shown as Lo
What to do when LO shows on the wine cellar cooling unitKind of codeSensors and probes
The controller has lost a sensible reading from one of its probes: the one sampling the cellar air, the one on the evaporator coil, or on a remote probe the lead that runs out to a rack. With no number it can trust, the unit may chill the room well below 55°F, stop and start every few minutes, or run on without end. A probe unplugged during a rack install, pinched behind a board or sitting in a draft from the door is ruled out before a new one is ordered.
Usually leads toCellar controller and sensor repair
Getting the controller, its display and its probes to read the cellar truthfully and call for cooling at the right time.
Shows up asCellar Cooling Unit Error Code
A cellar cooling unit error code appears as letters or digits on the controller, a flashing reading, a blinking light on the unit, or an alarm tone, sometimes while the cellar still holds its temperature.
MakeBreezaire
Visits to cellars cooled by a Breezaire unit, starting with a thermometer among the racks and a hand at the exhaust grille.
SourceBreezaire Sentry III Plus Controller owner's manual
Sentry III and Sentry III Plus controllers on WKL through-the-wall units and WKSL split systems. Older WKS splits built before mid-2010 used a manual thermostat and show none of these codes.
Before you book,
in this order.
Each step comes from Breezaire's own guidance for LO on its wine cellar cooling units. Follow it to the end: the last card says whether this is a visit.
Read the cellar with a separate thermometer; if it is near your setpoint, the sensor reading is the problem.
If a bottle probe is used, check that it has not ended up in the cold air outlet or against a cold surface.
If the room really is near freezing, unplug the unit and keep the door shut; Breezaire units only cool and have no heater.
If the thermometer and the display disagree, book a visit so the sensor circuit can be measured.
Still there?
It usually turns into cellar controller and sensor repair. Book with the code and the model number.
What not to do
LO is not the same as a cellar running a few degrees cold, which the Sentry III shows by flashing the temperature below 43°F. It is not Er either, because with LO the sensor still answers, just with a value too low to trust.
What you may
notice with it.
The wine cellar cooling unit problems LO tends to arrive with. Answer these at the wine cellar cooling unit before anyone is booked.
All problems
Cellar Cooling Unit Error Code
8 causes, cheapest first
Where LO usually leads
Cellar controller and sensor repair.
Breezaire
wine cellar cooling units.
Visits to cellars cooled by a Breezaire unit, starting with a thermometer among the racks and a hand at the exhaust grille.
Breezaire wine cellar cooling unit repair
Through-the-wall cellar cooling unit
A self-contained box set into an opening in the cellar wall: its cold face blows into the wine room, and its warm face breathes out into the room next door.
Split-system cellar cooling
An evaporator inside or beside the cellar and a condensing unit outside or in another room, joined by an insulated copper line set and charged on site.
In Breezaire's own words
If the temperature sensor inputs below 32°F (0°C) the display will flash “LO”
Every code on this site is taken from the manufacturer's documentation, never from a forum or a parts listing. Sentry III and Sentry III Plus controllers on WKL through-the-wall units and WKSL split systems. Older WKS splits built before mid-2010 used a manual thermostat and show none of these codes.
Breezaire LO wine cellar cooling unit repair,
where we come out.
The same visit in every metro below: the code, the model number, and a diagnosis before any part is ordered.
All service areasTampa BayFL · 31 areas
Miami / South FloridaFL · 47 areas
New York MetroNY · 75 areas
HoustonTX · 36 areas
ChicagoIL · 50 areas
Los AngelesCA · 95 areas
San DiegoCA · 31 areas
Questions
about LO.
Can I clear LO myself?
My cellar reads 55°F on a thermometer, so why does the Breezaire show LO?
Can a Breezaire freeze the cellar?
What is the difference between LO and a flashing temperature on a Breezaire?
Back to your everyday
Still showing LO?
When you book, type the code or the blink count as the controller shows it, add the full model number, and say what the thermometer in the cellar reads now — that gives the technician a head start.