What LA
actually means.

LA is the low temperature alarm, the counterpart of HA. With default settings it comes on once the cellar reads more than 10° under the setpoint for longer than the alarm delay, and it clears itself when the temperature returns. The controller leaves its outputs as they were.

Wine-Mate wine cellar cooling unit display

What to do when LA shows on the wine cellar cooling unit

Before you book,
in this order.

Each step comes from Wine-Mate's own guidance for LA on its wine cellar cooling units. Follow it to the end: the last card says whether this is a visit.

01

Check the setpoint; Wine-Mate recommends 55°F for aging wine.

02

Think about the space around the cellar: Wine-Mate lists a low ambient temperature as a cause, and its controllers can switch a separate forced-air heater.

03

Make sure the air probe is not sitting in the cold air leaving the unit.

04

If the room keeps falling with the unit running, book a visit to check the controller and probe.

Still there?

It usually turns into cellar cooling load and room check. Book with the code and the model number.

What not to do

LA on the display is not the -LA at the end of a split-system model number, which marks a low ambient kit. It also does not always mean the unit is overcooling, since a cold basement can take the room down while the unit sits idle.

What you may
notice with it.

The wine cellar cooling unit problems LA tends to arrive with. Answer these at the wine cellar cooling unit before anyone is booked.

All problems

Where LA usually leads

Cellar cooling load and room check.

Cooling load and room survey · lowest.

In Wine-Mate's own words

LA Low temperature alarm
Wine-Mate HZD self-contained cooling system manual Wine-Mate HZD self-contained cooling system manual Wine-Mate SSD split ceiling-mounted cooling system manual Wine-Mate HZD self-contained cooling system manual

Every code on this site is taken from the manufacturer's documentation, never from a forum or a parts listing. Current Wine-Mate five-button controller, as printed in the HZD, HZD-DE, 4510-series HZD, HTD, low-profile and SSH, SSD and SSO split-system manuals. Wi-Fi touchscreen and SMART controllers print no display codes.

Wine-Mate LA wine cellar cooling unit repair,
where we come out.

The same visit in every metro below: the code, the model number, and a diagnosis before any part is ordered.

All service areas
A couple lifting a bottle from a lit stone-walled wine cellar, the cooling unit's grille high on the far wall
For the heart of your home.

Questions
about LA.

Can I clear LA myself?
Check the setpoint; Wine-Mate recommends 55°F for aging wine. If it comes back, it needs a visit.
Is LA on my display related to the -LA in my model number?
No. On the display, LA is the low temperature alarm; at the end of a Wine-Mate split model number, LA means the condensing unit has a low ambient kit for sites below 50°F.
Can a Wine-Mate warm a cellar that is too cold?
The cooling unit does not heat, but controllers with the heater function can switch a forced-air heater through the SAA and SHy settings. With the factory values the heater comes on at 36°F and goes off at 40°F.
Why does LA show when my thermometer says the room is fine?
The probe may be sitting in the cold supply air or may need calibrating. Wine-Mate's ot setting offsets the probe by the difference between the real cellar temperature and the setpoint.

Back to your everyday

Still showing LA?

When you book, type the code or the blink count as the controller shows it, add the full model number, and say what the thermometer in the cellar reads now — that gives the technician a head start.